Kohler LH630-775 Service Manual page 102

Liquid-cooled horizontal crankshaft
Table of Contents

Advertisement

Delco-Remy Starters
Figure 8-15. Completed Delco-Remy Starter.
Starter Disassembly
1. Remove the hex nut and disconnect the positive
(+) brush lead/bracket from the solenoid
terminal.
2. Remove the three screws securing the solenoid to
the starter. See Figure 8-16.
Phillips Head
Screws
Torx Head Screws
Figure 8-16. Removing Solenoid Screws.
Electrical System and Components
3. If the solenoid was mounted with Phillips head
screws, separate the solenoid and plunger spring
from the drive end cap. If the solenoid was
mounted with external Torx head screws, the
plunger is part of the solenoid, unhook the
plunger pin from the drive lever. Remove the
gasket from the recess in the housing. See Figures
8-17 and 8-18.
NOTE: Test procedure for checking starter solenoid
on pages 8.21 and 8.22.
Figure 8-17. Solenoid Removed from Starter.
Figure 8-18. Removing Plunger.