12. Connect the Ethernet cable to the sensor as follows:
a) Align the tab of the RJ45 connector with the upper slot of the RJ45 jack on the sensor.
b) Align the three pins of the plug housing ring with the three notches of the receptacle on the sensor.
c) Press and rotate the plug housing until the pins click into the notches.
13. Using another RJ45 connector and the strain relief for the computer or network side, make the cable
connector as explained in steps 1 through 8.
In step 1, instead of using the plug housing, use the yellow strain relief (see Fig. 59).

Fig. 59: RJ45 strain relief connector kit (other end of the Ethernet cable)

14. Repeat steps 1 through 13 above for the other sensors.
54A0043_V4.0_EN / Leddar T16 – User Guide