Electrical; Environmental; Fig. 11: Leddar T16 "Tolling" Sensor Bottom View - Distances Between Mounting Threads; Table 12: Leddar T16 Electrical Specifications - Leddar T16 User Manual

Solid-state lidar traffic sensor
Hide thumbs Also See for T16:
Table of Contents

Advertisement

Fig. 11: Leddar T16 "Tolling" Sensor bottom view – Distances between mounting threads
4.3.

Electrical

Description
Power supply
Power supply tolerance
Power consumption (total)
4.4.

Environmental

Description
Operating temperature range
Humidity
Ingress protection rating
54A0043_V4.0_EN / Leddar T16 – User Guide
86.7 mm

Table 12: Leddar T16 electrical specifications

IEEE 802.3at PoE+ (Power over Ethernet Plus), 56 VDC
54 V to 57 V (56 V nominal)
It is strongly recommended not to exceed this
range as there is a surge protection at 58 V.
15 W (without heater)
25.5 W (with heater)

Table 13: Leddar T16 environmental specifications

−40 °C to +60 °C
100% RH
IP67
25.4 mm
Value
Value
23 | 72

Advertisement

Table of Contents
loading

Table of Contents