File Menu; Table 18: File Menu Options - Leddar T16 User Manual

Solid-state lidar traffic sensor
Hide thumbs Also See for T16:
Table of Contents

Advertisement

7.2.

File Menu

Option
Load Configura-
tion
Save Configura-
tion As...
Start Recording
Stop Recording
Import Configura-
tion
Record Replay
Start Data Logging
Stop Data Logging
Quit
54A0043_V4.0_EN / Leddar T16 – User Guide

Table 18: File menu options

This option allows you to load the sensor configuration previously saved in the
system as an .lto file. Choose the desired sensor configuration from the Open
dialog box.
You can also retrieve the configuration that was stored with a record file. In case
of system failure, you can load a sensor configuration and use this sensor
configuration to collect signal data according to a set of parameters (scanning,
distance measurements, etc.) and then analyze the collected data or the
information. In addition, if you have more than one sensor and you want to use
the same configuration for all of them, you must load the previously saved
configuration that you want to use for all your sensors. In this case, make sure
to assign a different name to all your sensors.
The sensors named differently will use the same configuration. See section
7.3.1.1 for more details.
This option allows you to save the configuration for a specific sensor to an *.lto
file from the Save As... dialog box.
This allows you to save settings and restore them in case of a system failure or
to revert to earlier settings. In addition, if you have more than one sensor and
you want to use the same configuration for all of them, save the configuration
you want to use for all your sensors. In this case, make sure to assign a
different name to all your sensors with a different name.
The sensors named differently will use the same configuration. See section
7.3.1.1 for more details.
Select the Start Recording option (shortcut: <F9>) to start recording detections
in an *.ltl file that can later be reloaded and replayed.
Select the Stop Recording option (shortcut: <F9>) to stop recording detections
of the *.ltl file.
See section 7.2.1.2 for more details.
This option allows you to import an *.ltl file.
Once you have completed a recording, you can review it by selecting Replay in
the File menu.
The Position slider allows you to move directly to the desired position. The
Playback Speed slider allows you to adjust the speed of the recording
playback.
See section 7.2.1.3 for more details.
Select the Start Data Logging option to start the log of receiving data or the
event log of the sensor. The event log is displayed in text format.
Select the Stop Data Logging option to stop the log of receiving data or the
event log of the sensor. The event log is displayed in text format.
See section 7.2.2.2 for more details.
Select Quit to exit the Leddar Configuration software.