6.2.6

IP switch actuator

Address the device via the " IP Touch 7"
1
2
Fig. 56:
IP switch actuator: commissioning mode
To address the device, perform the following steps:
1. Boot up the device.
The device boots up automatically when the power supply is connected.
If the device is already booted up, briefly interrupt the power supply of the device. The
device reboots.
The LED LED [1] lights up permanent after the automatic boot up.
2. Activating the "Commissioning mode":
After the device has booted and the LED [1] lights up permanent, briefly press the
"Reset" [2] button.
The LED [1] then flashes slowly. The flashing signals that the device is in
"Commissioning mode".
If no entry is made within the next 5 minutes, the device exits the "Commissioning
mode" automatically.
3. Switch to the indoor station.
System Manual
Commissioning
│81