ABB Welcome IP Manual page 35

Hide thumbs Also See for Welcome IP:
Table of Contents

Advertisement

Fig. 11:
Mounting in insulated facades: Inserting flush-mounted installation box
6. After the wall has been plastered, insert the flush-mounted box into the plastered box.
Attention:
Ensure that the encircling "Collar" of the flush-mounted installation box rests on the
facade. The encircling "Collar" of the flush-mounted installation box must not be
submerged in the facade. The device can then not be mounted later.
Tighten the flush-mounted installation box with the enclosed screws.
For this, use the four elongated holes in the bottom of the flush-mounted installation
box. Information on the elongated holes and boreholes is available in the graphics of
the drilling templates, see chapter 5.9.3 "Installation boxes - Surface mounting" on
page 57 and see chapter 5.9.4 "Installation boxes - flush-mounted installation" on
page 59.
Use the shorter or longer screws depending on the thickness of the plaster.
7. Mounting the outdoor station.
see chapter 5.3 "Outdoor stations" on page 39.
System Manual
Connection, installation / mounting
│35