ABB Welcome IP Manual page 121

Hide thumbs Also See for Welcome IP:
Table of Contents

Advertisement

Resetting the password of the 1st administrator.
The reset depends on the option of resetting that was selected for the commissioning of the
"Smart Access Point".
Option "Without MyBuildings account":
The password of the 1st administrator is reset on the rear side of the "Smart Access
Point" via the "Reset" button.
Option "With MyBuildings account":
The password of the 1st administrator is reset via a security release that is sent by e-
mail via the "myBuildings account".
Resetting the settings when the "Smart Access Point" can no longer be reached.
This can happen, for example, when the network settings are entered incorrectly.
1. Connect a PC with the "Smart Access Point".
More detailed information for connecting, see chapter 6.3.2 "Connecting a PC with the
"Smart Access Point "" on page 83.
2. Call up the start page of the "Smart Access Point" in a commercially available browser with
one of the following IP addresses.
Via the static IP address "10.0.0.1".
Via the IP address "192.168.3.1", if the "Smart Access Point" is in the Access-Point
mode.
The "Smart Access Point" switches automatically into the Access-Point mode after
every boot-up. The LED on the rear side of the device then lights up red.
Via an IP address that was assigned by the DHCP function of a router.
For this a router must be connected with the "Smart Access Point" in addition to the
PC.
The assigned address is obtained via the router. This depends on the router used.
The settings can be changed normally if the start page of the "Smart Access Point" is called up.
System Manual
Commissioning
│121