7.3.5
Connection of router / WLAN-WLAN
LAN 1
Master
02
Fig. 136: Adding a unit network router / WLAN-WLAN
This version allows up to 7 additional indoor stations (02 - 08) to be added in a unit as extension
unit.
No power supply can be set up for a WLAN connection. That is why a 24 V power supply is
required for the additional indoor station.
The IP addresses and the sub-net masks of the unit network are assigned automatically by the
DHCP function of the router.
Use the following steps to add additional indoor stations:
1. Search for devices in the "Smart Access Point".
–
Connect a PC with the "Smart Access Point".
–
In the main menu of the "Smart Access Point", change to the "Door communication"
function.
–
Search for all devices in the building network including the master indoor station.
Change to further indoor stations
2. Configure the additional indoor station (extension unit) for operation.
–
Change to the "Settings" / "Local settings" function in the additional indoor station.
–
Set the following points in the "Local settings" function:
Physical address (physical address, see chapter 6.4.3 "Reconnect the "Smart
■
Access Point"" on page 105).
Apart from the device number the physical address of the extension unit is identical
with the master address.
Mode: Extension unit
■
Device number: For the first additional indoor station the device number is set
■
automatically on 02. Each additional indoor station must be correspondingly counted
upwards.
System Manual
WLAN
DHCP
03
04
05
06
07
08
24 V DC
Case studies