Mounting In Hollow Walls - ABB Welcome IP Manual

Hide thumbs Also See for Welcome IP:
Table of Contents

Advertisement

5.5.2

Mounting in hollow walls

For mounting the installation boxes in hollow walls, perform the following points:
1. Cut a hole according to the size of the indoor station used into the facade.
The suitable template is enclosed with the flush-mounted installation box.
Dimensional drawings, see chapter 5.9.4 "Installation boxes - flush-mounted installation"
on page 59.
The installation depth of the flush-mounted installation box is 56 mm.
Fig. 26:
Mounting set for hollow wall boxes (83511-500)
To anchor the flush-mounted installation box in the cut-out, the separately available hollow-wall
mounting set (83511-500) is used.
2. Mount the mounting set on the flush-mounted installation box.
The clamps must then be located behind the flush-mounted installation box.
Fig. 27:
Mounting set for hollow wall box: Rubber bands
3. Connect the clamps with rubber bands.
System Manual
Connection, installation / mounting
│47