This area is, as the name indicates, private. The public area cannot access the private
area from behind the 1st indoor station. Access is also not possible from the private
area to the public area.
System modes of the "Smart Access Point"
For the later adding of the devices the system mode must already be specified during the
processing steps of the commissioning of the "Smart Access Point".
Mode "Multi-unit house / commercial":
For a building network.
The "Smart Access Point" is located in the building network.
The "Smart Access Point" has the static IP address "10.0.0.1".
The 10s IP address range is used to communicate with the "ABB-Welcome IP"
participants.
In parallel the "Smart Access Point" can be connected with a router per WLAN or
LAN and act as DHCP Client. Here the device receives an additional IP address
assigned by the router. This it uses in addition to its own 10s IP address.
Mode "One-family house / terraced house":
For a units network.
The "Smart Access Point" is located in the units network.
The "Smart Access Point" has the static IP address "10.0.0.1".
The 10s IP address range is used to communicate with the "ABB-Welcome IP"
participants.
In parallel the "Smart Access Point" can be connected with a router per WLAN or
LAN and act as DHCP Client. Here the device receives an additional IP address
assigned by the router. This it uses in addition to its own 10s IP address.