9.10 Setting up touch probes
Introduction
Refer to your machine manual.
In the machine parameter CfgHardware (no. 100102),
the machine manufacturer decides if the control shows
or hides the touch probes in the Device configuration
window.
The control allows you to set up and manage multiple touch probes.
Depending on the type of touch probe, you have the following
options for setting it up:
TT tool touch probe with radio transmission: Setup via MOD
function
TT tool touch probe with cable or infrared transmission: Setup via
MOD function or entry in machine parameters
TS 3-D touch probe with radio transmission: Setup via MOD
function
3-D TS touch probe with cable or infrared transmission: Setup via
MOD function, tool management, or touch probe table
Further information: "Touch probe table", Page 148
You can set up touch probes with the Set up touch probes MOD
function in the Machine settings group.
To open the Set up touch probes MOD function, proceed as follows:
Select the Machine settings group in the MOD menu
Select the Set up touch probes function
The control opens a pop-up window for device configuration on
the third desktop.