Testing and running | Skipping NC blocks
6.7
Skipping NC blocks
You can have NC blocks skipped in the following operating modes:
Test Run
Program run, full sequence
Program run, single block
Positioning w/ Manual Data Input
Operating notes:
This function does not work for TOOL DEF blocks.
After a power interruption the control returns to the
most recently selected setting.
The setting of the HIDE soft key is only effective in the
respective operating mode.
Test Run and Program Run
Application
In Test Run or Program Run, Full Sequence/Single Block operating
mode, the control can skip over NC blocks that you have preceded
by a slash (/):
Set the HIDE soft key to ON
The control skips the NC blocks.
Set the HIDE soft key to OFF
The control runs or tests the NC blocks.
Procedure
You can optionally hide NC blocks.
To hide NC blocks in the Programming mode:
Select the desired NC block
Press the INSERT soft key
The control inserts a slash (/).
To show NC blocks again in the Programming mode:
Select the hidden NC block
Press the REMOVE soft key
The control removes the slash (/).
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
6
261