Testing and running | Test run
Executing a Test Run up to a certain NC block
With the STOP AT function, the control executes a Test Run up to the
NC block with block number N.
To stop the Test Run at the desired NC block, proceed as follows:
Press the STOP AT soft key
Stop at: N = Enter the block number at which the
simulation should stop
Program: Enter the name of the NC program
containing the NC block with the selected block
number
The control shows the name of the selected
NC program.
If the simulation is to be stopped in an
NC program that has been called using PGM
CALL, then enter this name
Repetitions = If N is located in a program-section
repeat, enter the number of repeats that you want
to run.
Default 1: The control stops before N is simulated
Possibilities in stopped condition
If you interrupt the Test Run with the STOP AT function, you have the
following possibilities in this stopped condition:
Enable or disable NC block skip
Optional program stop enable or disable
Modify graphics resolution and model
Modify the NC program in the Programming operating mode
If you modify the NC program in the Programming operating mode,
the simulation behaves as follows:
Modification before the interruption point: The simulation restarts
at the beginning
Modification after the interruption point: Positioning at the
interruption point is possible with GOTO
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
6
267