Testing and running | Miscellaneous functions for path behavior
Deleting basic rotation: M143
Standard behavior
The basic rotation remains in effect until it is reset or is overwritten
with a new value.
Behavior with M143
The control deletes a basic rotation from the NC program.
The function M143 is not permitted with mid-program
startup.
Effect
M143 is effective only from the NC block in which it is programmed.
M143 becomes effective at the start of the block.
M143 clears the entries from the SPA, SPB and SPC
columns in the preset table. When the corresponding line
is reactivated, the basic rotation is 0 in all columns.
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
6
309