9.8. Error Process

The list below are the error codes that can occur when this program is executed.
9.8.1.
ExecPMCR Instruction Error
Error code that occurs when the ExecPMCR instruction ends abnormally.
● Output_PmrErrorID
After ExecPMCR is executed, the content of [ExecPMCR_instance.ErrorID] is set.
Code
16, 0000
16, 0400
16, 0406
16, 0407
16, 0800
16, 0801
Note
For details on ErrorID, see the following Appendices in "Machine Automation Controller NJ-series
Instructions Reference Manual" (W502): "A-1 Error Codes That You Can Check with ErrorID",
"A-2 Error Codes", "A-3 Instructions You Cannot Use in Event Tasks".
●Output_PmrErrorIDEx
When the value of [ExecPMCR_instance.ErrorID] is "16#0800", the content of
[ExecPMCR_instance.ErrorIDEx] is set.
Code
16, 00000000
16, 00001106
16, 00002201
16, 00002202
16, 00002401
Note
For details on ErrorIDEx, refer to "Chapter 2 Instruction Descriptions" - "Serial Communication
Instruction (ExecPMCR)" in the "Machine Automation Controller NJ/NX-series Instructions
Reference Manual (W502)".
Normal End
The input parameter of the instruction is out of the range of the input
variable.
The memory address or data size of the data specified by the instruction is
incorrect.
The results of instruction processing exceeded the data area range of the
output parameter.
An error occurred in Send / Receive of FINS Instruction.
FINS port is in use.
Normal End
The value of "SeqNo" is the Send / Receive sequence number that has not
been registered.
This command is already being executed. The values of "Busy" and
"J01_P2_PmrExecSta" are TRUE.
Cannot execute because the protocol is being switched.
The protocol macro data has an incorrect sum value, or data is being
transferred.