3
Check the received content
(read code) on the Watch Tab
Page of Sysmac Studio.
* In the example on the right, the
data stored in
Output_RecvMessage is
"377.477 170.371 0.299
1.000, LOT123456 DATE05 /
2012,123456", which is the
same as the trace data in Step
3 in Section 7.4.3.
* Output_RecvData [0] stores
the number of channels
(hexadecimal "001D") used to
store received data. The
content of the read barcode is
stored in Output_RecvData [1]
to [28], so the number of
channels used is 29 including
Output_RecvData [0].

8. Initializing the System

The explanations of procedures given in this document are based on the use of the factory
default settings.
When using a device that has been changed from the default settings, various settings may
not be able to proceed according to the procedures described.

8.1. Initializing the Controller

In order to initialize the controller, both the CPU Module unit and Serial Communication Unit
must be initialized. Please put the controller in Program Mode before initialization.
8.1.1.
Serial Communications Unit
To return the Serial Communication Unit's settings to their default settings, select [Edit Special
Unit Settings] for [CJ1W-SCU22] in [CPU EXPANSION RACKS] in "Sysmac Studio".
Received content (Hexidecimal)
・Output_RecvData[0]:"001D"
・Output_RecvData[1]:"3337"
・Output_RecvData[2]:"372E"
・Output_RecvData[2]:"3437"
・Output_RecvData[26]:"3132"
・Output_RecvData[27]:"3334"
・Output_RecvData[28]:"3536"
Number of channels used to
store received data
29 channels, [0] to [28]
Barcode value (String)
Output_RecvMessage
377.477
170.371
0.299
1.000,LOT123456
DATE05/2012,123456