Verify The Operation Of A Replacement Internal M.2 Boot Module - Dell EMC PowerStore 500T Installation And Service Manual

Hide thumbs Also See for EMC PowerStore 500T:
Table of Contents

Advertisement

NOTE:
Run the command immediately after inserting the node to prevent any possibility of a time out issue.
The reimage procedure takes approximately 40 to 50 minutes to complete.
2. Review the output of the svc_repair command. The output provides useful information as the procedure runs, so allow
the session to remain open so you can monitor the progress. The following output is an example. Your output may differ
depending on which node is being reimaged.
SVC:cyc@CHXXXXX-A ~]$ svc_repair
PLEASE READ CAREFULLY!!! Requested operation will reformat peer node, all data will
be removed
Print 'YES' (All caps) if you want to continue recovery:
YES
CSU - initiating peer recovery. running on node A, recovering node B
may differ)
CSU - creating grub config
CSU - starting recovery container (afeoscyc-mw.cec.lab.emc.com/centos7/
recovery:v7.6.1327915), and booting peer node from PXE
CSU - sending power cycle command to peer
CSU - installation started, waiting for node to become reachable by ping, please be
patient, this might take a long time
CSU - still waiting for ping...
"
"
"
CSU - still waiting for ping...
CSU - peer node is reachable, starting health verification
CSU - waiting for node to answer via ssh, and checking installation flag (retry 10
out of 10)
CSU - waiting for node to answer via ssh, and checking installation flag (retry 9 out
of 10)
CSU - installation flag detected on peer node, reimage successfully performed
CSU - verifying peer is healthy, please wait...
"
"
"
CSU - verifying peer is healthy, please wait...
CSU - SUCCESS: node is healthy and ready for use!
=====================================================
Successfully finished peer recovery - peer node is healthy
Next steps
If the svc_repair command fails, run it a second time. If the reimage fails again, contact your service provider.
FAILED to recover peer - manual intervention required
=====================================================
Error 1: Reimaging of peer node failed - check journalctl for details

Verify the operation of a replacement internal M.2 boot module

Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you replaced the internal M.2 boot module.
3. On the Components card, under Internal View, expand the node that includes the internal M.2 boot module, and then
select the relevant InternalM.2BootModule.
The status of the replacement internal M.2 boot module should read Healthy. If the status is still Faulted, wait a few
minutes and refresh PowerStore Manager. If the status does not change, ensure that the internal M.2 boot module is
correctly seated, or contact your service provider.