Dell SCv3000 and SCv3020 Storage System
Owner's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Dell SCv3000

  • Page 1 Dell SCv3000 and SCv3020 Storage System Owner’s Manual...
  • Page 2 WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
  • Page 3: Table Of Contents

    SCv3000 and SCv3020 Storage System Drive Numbering ..................8 SCv3000 and SCv3020 Storage Controller Features and Indicators ........................8 SCv3000 and SCv3020 Storage Controller 2 Replacing SCv3000 and SCv3020 Storage System Components........11 ................................11 Safety Precautions ............................. 11 Installation Safety Precautions ............................
  • Page 4: About This Manual

    The information provided in this manual is intended for use by Dell end users. Contacting Dell Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services might not be available in your area.
  • Page 5: Scv3000 And Scv3020 Storage System Hardware

    SCv3000 and SCv3020 Storage System Hardware The SCv3000 and SCv3020 storage system ships with Dell Enterprise Value drives, two redundant power supply/cooling fan modules, and two redundant storage controllers. Each storage controller contains the front-end, back-end, and management communication ports of the storage system.
  • Page 6: Scv3000 And Scv3020 Storage System Back-Panel View

    Contains a 1485 W power supply and fans that provide cooling for the storage module (2) system, with AC input to the power supply of 200–240 V. In Dell Storage Manager, the power supply/cooling fan module on the left side of the back panel is Power Supply 1 and power supply/cooling fan module on the right side of the back panel is Power Supply 2.
  • Page 7: Scv3000 And Scv3020 Storage System Drives

    5 to 9 from left to right. Dell Storage Manager identifies drives as XX-YY, where XX is the number of the unit ID of the storage system and YY is the drive position inside the storage system.
  • Page 8: Scv3000 And Scv3020 Storage Controller Features And Indicators

    Figure 5. SCv3020 Storage System Drive Numbering SCv3000 and SCv3020 Storage Controller Features and Indicators The SCv3000 and SCv3020 storage system includes two storage controllers in two interface slots. SCv3000 and SCv3020 Storage Controller The following figure shows the features and indicators on the storage controller.
  • Page 9 The SAS ports on SAS I/O cards do not have LEDs. Identification LED Blinking blue continuously – A command was sent by Dell Storage Manager to the storage system to make the LED blink so that users can identify the storage system in the rack.
  • Page 10 Off – No connectivity • Steady green, left LED – Link (full speed) • Steady amber, left LED – Link (degraded speed) • Blinking green, right LED – Activity NOTE: The mezzanine card does not support DCB. SCv3000 and SCv3020 Storage System Hardware...
  • Page 11: Replacing Scv3000 And Scv3020 Storage System Components

    Always follow these safety precautions to avoid injury and damage to Storage Center equipment. If equipment described in this guide is used in a manner not specified by Dell, the protection provided by the equipment could be impaired. For your safety and protection, observe the rules described in the following sections.
  • Page 12: Electrostatic Discharge Precautions

    Follow these guidelines to protect your equipment from ESD: • Dell recommends that you always use a static mat and static strap while working on components in the interior of the chassis. • Observe all conventional ESD precautions when handling plug-in modules and components.
  • Page 13: Shut Down The Storage System And Expansion Enclosures

    Shut Down the Storage System and Expansion Enclosures If the replacement component is not hot-swappable, use the Dell Storage Manager to shut down the storage system and expansion enclosures. Shutting down the storage system and expansion enclosures results in a system outage, so plan to perform these procedures during a maintenance window.
  • Page 14: Install The Front Bezel

    The SCv3000 and SCv3020 storage system supports hot-swappable hard drives. A minimum of 4 SSDs or 7 drives must be installed in the chassis or in an expansion enclosure. The SCv3000 and SCv3020 storage system supports a maximum of 16 or 30 drives installed in the chassis. The drives are installed from left to right, and then top to bottom.
  • Page 15: Install The Replacement Drive

    • Use Dell Storage Manager to edit the Storage Center settings and set the operation mode of the Storage Center to Maintenance mode. Steps Remove the front bezel from the storage system. Locate the failed hard drive in the storage system.
  • Page 16: Install The Rack Rails

    Remove the storage system from the rack. Remove the rack rails from the rack. Install the Rack Rails Perform the following steps to install rack rails for an SCv3000 and SCv3020 storage system. Steps Install the replacement rack rails in the rack.
  • Page 17: Power Supply And Cooling Fan Modules

    Power Supply and Cooling Fan Modules The SCv3000 and SCv3020 storage system supports two hot-swappable power supply/cooling fan modules. The cooling fans that cool the storage system and the power supplies are integrated into the power supply/cooling fan module and cannot be replaced separately.
  • Page 18: Identify The Failed Cooling Fan

    Use this procedure to replace failed a power supply/cooling fan module. Prerequisites Use Dell Storage Manager to send SupportAssist information to Dell Technical Support. Use Dell Storage Manager to edit the Storage Center settings and set the operation mode of the Storage Center to Maintenance mode. About this task You can replace power supply/cooling fan modules one at a time without shutting down the storage system.
  • Page 19 In Dell Storage Manager, make sure that the replacement power supply is recognized and shows as up and running. Next step Use Dell Storage Manager to edit the Storage Center settings and set the operation mode of the Storage Center to Normal mode.
  • Page 20: Scv3000 And Scv3020 Storage System Technical Specifications

    This appendix contains the technical specifications for the SCv3000 and SCv3020 storage system. Technical Specifications The technical specifications of the SCv3000 and SCv3020 storage systems are displayed in the following tables. Drives SCv3000 Up to 16 3.5-in. hot-swappable hard drives (12 Gb SAS) SAS hard drives SCv3020 Up to 30 2.5-in.
  • Page 21 44.50 cm (17.5 in.) SCv3000 81.91 cm (32.25 in.) Depth SCv3020 78.27 cm (31 in.) SCv3000 45 kg Approximate weight (maximum configuration) SCv3020 43 kg Approximate weight without drives 32.5 kg (72 lb) SCv3000 and SCv3020 Storage System Technical Specifications...
  • Page 22 ≤35°C (95°F) Maximum Rating – Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft) Storage 12,000 m (39,370 ft) Airborne Contaminant Level Class G1 or lower as defined by ISA-S71.04-1985 SCv3000 and SCv3020 Storage System Technical Specifications...