d. WIDTH
• Adjust the width of the effective screen in each signal input
FORMAT, each SCAN SIZE and each ASPECT.
• For the adjustment procedures, refer to 4.4 (8).
e. HEIGHT
• Adjust the height of the effective screen in each signal input
FORMAT, each SCAN SIZE and each ASPECT.
• For the adjustment procedures, refer to 4.4 (8).
f. TRAPEZOID
• Adjust the TRAPEZOID of the effective screen in each
FORMAT.
• For the adjustment procedures, refer to 4.4 (8).
g. SIDE PIN
• Adjust the side pin of the effective screen in each FORMAT
• For the adjustment procedures, refer to 4.4 (8).
4.3 Procedures for registering data in
memory or changing data

(1) Registering/changing PRESET data

• Set various preset data on three types of menus that are
displayed using the PRE switch.
• The preset data displayed on the page-3 screen must be
individually set according to the FORMAT or SCAN SIZE
as tabulated in Chapter 7 "Memo".
CAUTION
When changing the preset data displayed on the page-3 screen,
data in a different format will be invoked if the switching below
is done during data change.
Do not perform the switching below during data change.
• Input signal format switching
• Input channel switching
• Scan size switching
• Aspect switching
(Ex.) Changes in H.PHASE, H.CENT, V.CENT, WIDTH,
HEIGHT, TRAPEZOID and SIDE PIN
MENU/ENT
PRE
ESC
A
INPUT
ANALOG
SDI
B
1. Set SCAN SIZE to UNDER SCAN using the U-SCAN switch
and display the 10-division crosshatch using the MARK
switch.
2. Press the PRE switch three times to display the menu above.
3. H.PHASE change
Move the cursor to [PHA] using
4. Centering change
Move the cursor to [CENT] using
longitudinal: V.CENT) and make a change using
a way that the screen is centered in the horizontal and vertical
directions.
5. Size change
Move the cursor to [SIZE] using
longitudinal: HEIGHT) and change the width and height
using
.
6. Trapezoid change
Move the cursor to [
distortion using
7. SIDE PIN change
Move the cursor to [
using
.
8. Data registration
On completion of data change, pressing the MENU/ENT
switch twice registers the changed data.
22
*H.PHASE*
PHA
CENT
SIZE
Cursor
and change it using
(lateral: H.CENT,
(lateral: WIDTH,
] using
and change the trapezoidal
.
] using
and change SIDE PIN
.
in such