Fronius Trans Pocket 1500 Service Instructions Manual page 186

Table of Contents

Advertisement

Available languages

Available languages

Fitting the FPA15
board
(continued)
Fig.14
(66)
Fig.15
(6)
Fig.16
Fig.17
(68)
(55)
(72)
(73)
(5)
(40)
(41)
72
- Fasten the X3 cable (blue) (72) and
the by-pass capacitors (73) onto the
copper bracket (55), using the 5x12 -
TX20 screw (68)
- Tighten the 5x12 - TX20 screw (68)
with a torque of 2 Nm
- Thigthen the round nut (66)
- Replace the setting dial (6)
Note! When thigthening the
fixing nut for the "Welding-
amperage setting dial", hold the
dial (6) firmly
- Thigthen the fixing nut of the setting
dial (6) with the socket spanner (width-
across 7)
- Replace the cap to the "Welding-
amperage setting dial" (6)
- Plug the 10-pole Molex plug (41) onto
(42)
board LCA15
- Plug the 2-pole Molex plug (40) onto
board LCA15
- Arrange the ribbon cable (42) above
the cable harness, as shown in Fig.17
- Plug the ribbon cable (42) to board
FPA15 (5)