Quick Start Guide - Analog Devices EV-ADF5904SD2Z User Manual

Evaluation board for the adf5904 4-channel, 24 ghz receiver downconverter
Table of Contents

Advertisement

EV-ADF5904SD2Z User Guide

QUICK START GUIDE

Follow these steps to quickly evaluate the ADF5904.
1.
Connect the power supply to the EV-ADF5904SD2Z:
a.
5 V to Banana Connector P2
b.
GND to Banana Connector P1
2.
Install the
ADF5904
software.
3.
Connect the SDP-S motherboard to the PC and to the
EV-ADF5904SD2Z
evaluation board.
4.
Follow the hardware driver installation procedure.
5.
Run the
ADF5904
software.
6.
Select the
ADF5904
device and the USB board in the
Select Device and Connection tab of the software front
panel window (see Figure 2).
7.
Check that the message SDP board connected appears at
the bottom left of the software window (see Figure 2).
8.
Connect an ac-coupled RF source to LOIN SMA and
connect an ac-coupled RF source to one of the RXxIN
input SMAs.
9.
In the Main Controls tab, click Initialize.
10. Connect the corresponding Rx baseband channel output to
an oscilloscope.
11. Measure the results.