dsp board led troubleshooting
1. BATTERY INPUT ERROR
8. MOTOR OVERLOAD
14. PRIMARY/SECONDARY
ID plug MUST
be plugged in.
DSP Board LED
Problem Condition
"BATTERY IN ERROR" LED is ON.
"BATTERY IN USE" LED is ON
"BATTERY VOLTAGE (E 1/2 F)" LEDs,
only "E" is ON.
"REPLACE BATTERY" LED is ON.
"BATTERY IN USE" and "POWER"
LED are FLASHING
"UL Entrap" LED is ON
"ERD" LED is FLASHING
"PHOTO CLS" LED is ON
"CLS ONLY 10k" LED is ON
"PHOTO CLS" LED is flashing
"CLS ONLY 10k" LED is flashing
"OPEN ONLY" LED is ON
"OPEN ONLY" LED is FLASHING
"MAX SENSE" LED is ON
"OBD PORT" LED is FLASHING
"PROGRAM" LED is FLASHING
MAX Arm/Ultra Arm V1
BATTERY
2. BATTERY IN USE
INPUT
3. BATTERY VOLTAGE
4. REPLACE BATTERY
5. POWER
POWER /
SOLAR IN
6. ERD
7. MAX SENSE
MODULE
PORT
RESET
10. OBD PORT
1
2
11. PROGRAM
ALARM
3
4
5
ID PLUG
6
ERROR
12. ID PLUG ERROR
1
2
3
ID
4
PLUG
5
13. SOLAR MODE
6
7
8
9
10
EXIT PWR
15. EXIT LOOP
EXIT
GND
16. CENTER LOOP
CENTER
LOOP PWR
17. SAFETY LOOP
SAFETY
FAULTS
18. 12 VDC
24VDC OUTPUT
GND
19. 24 VDC
12VDC OUTPUT
GND
40. CLOSING GATE SPEED
Normal
LED
1
•
"BATTERY Plug" not plugged in to "BATTERY INPUT" port.
•
AC power is lost, operator is in battery back-up mode.
OFF
2
•
Check if Toroid box AC POWER ON/OFF SWITCH is ON.
•
Battery is very LOW. Check if toroid box AC power ON/OFF switch is ON. If so, check AC power.
OFF
3
•
Battery needs to be replaced if BATTERY TEST fails and "REPLACE BATTERY" LED is ON.
OFF
4
•
Battery not plugged in to BATTERY INPUT port.
OFF / ON
2 / 5
•
An entrapment event has occurred, check if an entrapment sensor was triggered (see if PHOTO CLS,
ON
37
OPEN ONLY, or OPEN/CLS LEDs are on).
•
An ERD event may have occurred. Check for gate obstruction.
ON
6
•
ERD sensitivity is too high for application. Re-adjust ERD setting, (see
•
Sensor on PHOTO CLS or CLS ONLY 10k inputs (photocell or edge) may have detected an obstruction
OFF
30 / 34
while closing gate.
•
Photocell on PHOTO CLS or CLS ONLY 10k inputs is misaligned with reflector.
•
Sensor on PHOTO CLS or CLS ONLY 10k inputs (photocell or edge) may not be wired properly, (see
OFF
30 / 34
•
Sensor is NOT a N.C. monitored sensor that is UL 325 2018 compliant.
•
Sensor might need to be re-learned, (see
•
Sensor is damaged or malfunctioning.
•
Sensor on OPEN ONLY input (photocell or edge) may have detected an obstruction while cycling gate.
OFF
29 / 33
•
Photocell on OPEN ONLY input is misaligned with reflector.
•
Sensor on OPEN ONLY input (photocell or edge) may not be wired properly, (see
OFF
29 / 33
•
Sensor is NOT a N.C. monitored sensor that is UL 325 2018 compliant.
•
Sensor on OPEN ONLY is damaged or malfunctioning.
•
Sensor might need to be re-learned, (see
•
MOST sensitive setting for ERD entrapment detection. Select a less sensitive setting (recommend level
OFF
7
10 thru 16), (see
•
Up to 8000 event history and error codes are being downloaded to connected flash drive. Up to 5 min.
OFF
10
•
Program button has been pressed and programming mode is active. Press button again to leave
OFF
11
programming mode.
Table continued on next page
BATTERY
DSP ARM CONTROLLER
BATTERY VOLTAGE
INPUT
ERROR
E
1/2
F
BATTERY
BACKUP MODE
BATTERY
LEAVE
OPEN
IN USE
OPEN
1 TIME
REPLACE
LEAVE
BATTERY
BATTERY
CLOSED
TEST
POWER
ERD SENSITIVITY
14
12
14
12
16
16
MIN
MIN
ERD
ERD
1
9
1
9
MOTOR
MOTOR
MAX
MAX
SENSE
OVER
SENSE
OVER
3
7
7
3
LOAD
LOAD
OPENING
CLOSING
OBD PORT
BLACK BOX
MAXIMUM CONTROLS
OFF
DSP ARM CONTROLLER
MOTION CONTROL
PROGRAMMING
OPEN
STOP
CLOSE
PROGRAM
OFF
ANTI-
PUSH
PULL
TAILGATE
SOLAR MODE
OPEN
OPEN
LOOP
OFF
ON
OFF
ON
GATE
LOOP
CLOSING GATE SPEED
LOOP
OPERATOR
MIN
MIN
MAX
MAX
SINGLE
DUAL
MOTOR 1
MOTOR 2
Solution(s) for
Problem Condition
15
15
).
11
[ + ]
MOTOR 1
INPUTS
[-]
[ + ]
MOTOR 2
INPUTS
[-]
LIMIT 1
MOTOR 1
20. CLOSE TIMER
LIMIT 2
LIMIT 1
MOTOR 2
CLOSE
LIMIT 2
TIMER
LIMIT 1
MIN
MAX
MOTOR 1
GND
OFF
LIMITS
LIMIT 2
22. ON/OFF BATTERY
23. ANTI-TAILGATE
LIMIT 1
MOTOR 2
GND
24. OPEN LEFT
LIMITS
LIMIT 2
ON/OFF
BATTERY
25. OPEN RIGHT
JOG
GATE OPEN
26. GATE OPEN
COM
GATE CLOSED
27. GATE CLOSED
GND
OPEN
CLOSE
NO
28. MAGLOCK
MAG
LOCK
COM
NC
MAGLOCK
29. OPEN ONLY NC
DELAY
OPEN ONLY NC
PHOTO CLS NC
30. PHOTO CLOSE NC
OFF
2.5 sec
OPEN / CLS NC
31. OPEN / CLOSE NC
1.5 sec
12VDC OUT
GND
32. 12VDC OUT
OPEN ONLY 10K
UL
ENTRAP
CLS ONLY 10K
33. OPEN ONLY 10K
OPEN / CLS 10K
34. CLOSE ONLY 10K
12VDC OUT
35. OPEN / CLOSE 10K
GND
36. 12VDC OUT
37. UL ENTRAPMENT
38. GATE TAMPER
39. GATE DISABLE
).
11
).
).
).