additional features

open / stop / close inputs

The OPEN/STOP/CLOSE inputs will allow a standard 4-wire 3-Button Station
and a External Alarm RESET Button to be connected.
Corresponding LEDs will light when each button is activated.
External Alarm Reset Button
An external Alarm Reset button can to be installed in a secure
place and connected as shown to quickly SHUT-OFF a
sounding alarm. Otherwise alarm can be shut-off by the
RESET ALARM button on the side of control box (see below).

reset alarm button / jog gate open/close

C
o
n
t
B
r
o
o
x
l

programming

BATTERY
BATTERY VOLTAGE
INPUT
ERROR
E
1/2
F
BATTERY
BATTERY
INPUT
BACKUP MODE
BATTERY
LEAVE
OPEN
IN USE
OPEN
1 TIME
REPLACE
LEAVE
BATTERY
BATTERY
CLOSED
TEST
POWER /
SOLAR IN
POWER
ERD SENSITIVITY
14
12
14
16
16
PROGRAM button
MIN
MIN
ERD
1
9
1
MAX
MOTOR
MAX
MODULE
SENSE
OVER
SENSE
PORT
3
7
3
LOAD
OPENING
CLOSING
OBD PORT
BLACK BOX
MAXIMUM CONTROLS
M CONTROLS
RESET
OFF
DSP ARM CONTROLLER
P ARM CONTROLLER
1
2
ALARM
3
4
5
PROGRAMMING
MOTION CONTROL
ID PLUG
6
ERROR
1
2
3
ID
4
PLUG
5
6
7
OPEN
EN
STOP
STOP
PROGRAM
8
9
10
OFF
ANTI-
EXIT PWR
TAILGATE
SOLAR MODE
EXIT
LOOP
OFF
ON
GND
OFF
ON
CENTER
LOOP
LOOP PWR
CLOSING GATE SPEED
SAFETY
LOOP
OPERATOR
MIN
FAULTS
MAX
SINGLE
DUAL
24VDC OUTPUT
GND
MOTOR 1
12VDC OUTPUT
GND
Press and hold PROGRAM button for 5 seconds
to enter program mode.
MAX Arm/Ultra Arm V1
Reset Alarm Button:
If the Alarm Sounds During Normal Gate Operation:
obstructions before completing a gate cycle, the alarm will sound and the gate will PAUSE in the
position where the second obstruction occurred.
CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the alarm reset button on the
control box to shut off the alarm and reset the gate.
NOTE: Alarm will automatically shut-off after five minutes but will not allow gate to operate until the
alarm reset button is pressed.
R M
L A
T A
S E
R E
Jog Gate Open/Close:
A T
E
S E
L O
G G
/ C
J O
E N
O P
The JOG key switch can open or close the gate electronically. Insert key on control box, turn and
HOLD (in either direction) to MOVE gate. Jog switch will operate BOTH arms together for bi-parting
gates. NOTE: OWNER of the gate operator is responsible for the KEY availability.
JOG buttons on circuit board function the same as JOG key switch.
CAUTION:
Keep pedestrians and vehicles clear
of the gate while it is moving.
DSP ARM CONTROLLER
MOTOR 1
[+]
INPUTS
[-]
[+]
MOTOR 2
INPUTS
[-]
LIMIT 1
MOTOR 1
LIMIT 2
LIMIT 1
MOTOR 2
CLOSE
LIMIT 2
TIMER
12
ERD
9
MOTOR
LIMIT 1
LIMIT 1
OVER
7
MIN
MIN
MAX
MAX
MOTOR 1
MOTOR 1
LOAD
GND
GND
OFF
OFF
LIMITS
LIMITS
LIMIT 2
LIMIT 2
LIMIT 1
LIMIT 1
MOTOR 2
MOTOR 2
GND
GND
LIMITS
LIMITS
LIMIT 2
LIMIT 2
ON/OFF
ON/OFF
BATTERY
BATTERY
JOG
GATE OPEN
GATE OPEN
COM
COM
GATE CLOSED
GATE CLOSED
GND
GND
OPEN
OPEN
CLOSE
CLOSE
CLOSE
CLOSE
NO
NO
MAG
MAG
LOCK
LOCK
CO
COM
NC
PUSH
PULL
MAGLOCK
OPEN
OPEN
DELAY
OPEN ONLY NC
PHOTO CLS NC
GATE
OFF
2.5 sec
OPEN / CLS NC
1.5 sec
12VDC OUT
MIN
GND
OPEN ONLY 10K
MAX
UL
ENTRAP
CLS ONLY 10K
MOTOR 2
OPEN / CLS 10K
12VDC OUT
GND
3-Button
Station
OPEN
STOP
STOP
Com
CLOSE
Com
When the gate encounters TWO consecutive
Next
Back
MOTION CONTROL
OPEN
CLOSE
STOP
Programming Assistant Buttons
To enter PROGRAM mode, press and hold PROGRAM button for 5 seconds.
Follow instructions on-screen using the 4 buttons shown above to program
with. Press ONLY PROGRAM button again to end programming when finished.
In PROGRAM mode, you can do the following:
Scroll through most recent errors.
View input voltage (DC voltage).
View average current gate consumption.
View cycle count.
Program date and time.
Turn on/off other advanced features.
BATTERY
INPUT
BATTERY VOLTAGE
ERROR
E
1/2
F
BATTERY
BATTERY
INPUT
BACKUP MODE
BATTERY
LEAVE
IN USE
OPEN
REPLACE
LEAVE
BATTERY
BATTERY
CLOSED
POWER /
TEST
SOLAR IN
POWER
ERD SENSITIVITY
14
12
16
MIN
ERD
1
9
MOTOR
MODULE
MAX
MAX
SENSE
OVER
SENSE
PORT
3
7
LOAD
OPENING
OBD PORT
BLACK BOX
MAXIMUM CONTROLS
OFF
DSP ARM CONTROLLER
1
PROGRAMMING
MOTION CONTROL
OPEN
PROGRAM
PROGRAM
10
ANTI-
EXIT PWR
TA
TAILGATE
SOLAR MODE
SOLAR MODE
EXIT
LOOP
OFF
OFF
GND
S
OFF
ON
ON
E S
CENTER
LOOP
LOOP PWR
CLOSING
CLOSING GATE SPEED
P R
OPERATOR
LOOP
MIN
MIN
MAX
SINGLE
DUAL
T
S E
GND
GND
MOTOR 1
R E
12VDC OUTPUT
12VDC OUTPUT
GND
ND
t o
External Alarm
Reset Button
JOG
OPEN CLOSE
Up
Down
JOG
OPEN CLOSE
DSP ARM CONTROLLER
MOTOR 1
[+]
INPUTS
[-]
[+]
MOTOR 2
OPEN
[-]
INPUTS
1 TIME
LIMIT 1
MOTOR 1
LIMIT 2
LIMIT 1
MOTOR 2
CLOSE
LIMIT 2
TIMER
14
12
16
MIN
ERD
1
9
MOTOR
OVER
LIMIT 1
3
7
LOAD
MIN
MAX
MOTOR 1
GND
CLOSING
OFF
LIMITS
LIMIT 2
LIMIT 1
MOTOR 2
GND
LIMITS
ON/OFF
LIMIT 2
BATTERY
JOG
GATE OPEN
COM
GATE CLOSED
GND
OPEN
CLOSE
STOP
CLOSE
NO
MAG
LOCK
COM
NC
PUSH
PULL
MAGLOCK
OPEN
OPEN
DELAY
OPEN ONLY NC
ON
PHOTO CLS NC
GATE
OFF
2.5 sec
OPEN / CLS NC
1.5 sec
12VDC OUT
MIN
M
GND
MAX
MAX
OPEN ONLY 10K
UL
ENTRAP
CLS ONLY 10K
MOTOR 2
MOTOR 2
OPEN / CLS 10K
12VDC OUT
GND
35

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAX ARM and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Max ultra arm

Table of Contents