AC Powered control box
13.5" (343 mm)
BATTERY
DSP ARM CONTROLLER
INPUT
BATTERY VOLTAGE
ERROR
E
1/2
F
BATTERY
BATTERY
INPUT
BACKUP MODE
BATTERY
LEAVE
OPEN
IN USE
OPEN
1 TIME
REPLACE
LEAVE
BATTERY
BATTERY
CLOSED
TEST
POWER /
SOLAR IN
POWER
ERD SENSITIVITY
14
12
14
12
16
16
MIN
ERD
MIN
1
9
1
MODULE
MAX
MOTOR
MAX
SENSE
OVER
SENSE
PORT
3
7
3
7
LOAD
OPENING
CLOSING
OBD PORT
BLACK BOX
MAXIMUM CONTROLS
RESET
OFF
DSP ARM CONTROLLER
1
2
ALARM
3
4
5
PROGRAMMING
MOTION CONTROL
ID PLUG
6
ERROR
1
2
3
ID
4
PLUG
5
6
7
PROGRAM
OPEN
STOP
8
9
10
OFF
ANTI-
EXIT PWR
PUSH
SOLAR MODE
TAILGATE
OPEN
EXIT
LOOP
OFF
ON
GND
OFF
ON
GATE
CENTER
LOOP
LOOP PWR
CLOSING GATE SPEED
SAFETY
LOOP
OPERATOR
MIN
MIN
FAULTS
MAX
MAX
SINGLE
DUAL
24VDC OUTPUT
GND
MOTOR 1
12VDC OUTPUT
GND
AVERTISSEMENT: pour ne pas compromettre la
protection contre les risques d'incendie, utiliser un
fusible de mêmes type et caractéristiques nominales.
WARNING: For continued protection
EXIT
CENTER
SAFETY
J3
J4
J5
solar powered control box
13.5" (343 mm)
BATTERY
DSP ARM CONTROLLER
BATTERY VOLTAGE
INPUT
ERROR
E
1/2
F
BATTERY
BATTERY
INPUT
BACKUP MODE
BATTERY
LEAVE
OPEN
IN USE
OPEN
1 TIME
REPLACE
LEAVE
BATTERY
BATTERY
CLOSED
TEST
POWER /
SOLAR IN
POWER
ERD SENSITIVITY
14
12
14
12
16
16
MIN
MIN
ERD
1
9
1
MOTOR
MODULE
MAX
MAX
SENSE
OVER
SENSE
PORT
3
7
3
7
LOAD
OPENING
CLOSING
OBD PORT
BLACK BOX
MAXIMUM CONTROLS
RESET
OFF
DSP ARM CONTROLLER
1
2
ALARM
3
4
5
MOTION CONTROL
PROGRAMMING
ID PLUG
6
ERROR
1
2
3
ID
4
PLUG
5
6
7
PROGRAM
OPEN
STOP
8
9
10
OFF
ANTI-
PUSH
EXIT PWR
TAILGATE
SOLAR MODE
OPEN
EXIT
LOOP
OFF
ON
GND
OFF
ON
GATE
CENTER
LOOP
LOOP PWR
CLOSING GATE SPEED
OPERATOR
SAFETY
LOOP
MIN
MIN
FAULTS
MAX
MAX
SINGLE
DUAL
24VDC OUTPUT
MOTOR 1
GND
12VDC OUTPUT
GND
30 Amp Fuses
On
EXIT
CENTER
SAFETY
Off
SOLAR
J3
J4
J5
+
Loop Rack
(Optional)
2
specifications
MOTOR 1
[+]
INPUTS
[-]
MOTOR 2
[+]
INPUTS
[-]
LIMIT 1
MOTOR 1
LIMIT 2
LIMIT 1
MOTOR 2
CLOSE
LIMIT 2
TIMER
ERD
9
MOTOR
OVER
LIMIT 1
MIN
MAX
MOTOR 1
LOAD
GND
OFF
LIMITS
LIMIT 2
LIMIT 1
MOTOR 2
GND
LIMITS
LIMIT 2
ON/OFF
BATTERY
JOG
GATE OPEN
COM
GATE CLOSED
GND
OPEN
CLOSE
CLOSE
MAG
NO
LOCK
COM
NC
MAGLOCK
PULL
17"
OPEN
DELAY
OPEN ONLY NC
PHOTO CLS NC
OFF
2.5 sec
OPEN / CLS NC
432 mm
1.5 sec
12VDC OUT
GND
UL
OPEN ONLY 10K
ENTRAP
CLS ONLY 10K
MOTOR 2
OPEN / CLS 10K
12VDC OUT
GND
7A
against fire, replace only with the
FUSE
same type and rating of fuse.
On
Select Input Voltage
115VAC or 230VAC
Off
POWER
115VAC
POWER IN
3A max
(AC)
[+]
MOTOR 1
INPUTS
[-]
MOTOR 2
[+]
INPUTS
[-]
LIMIT 1
MOTOR 1
LIMIT 2
LIMIT 1
MOTOR 2
CLOSE
LIMIT 2
TIMER
ERD
9
MOTOR
LIMIT 1
OVER
LOAD
MIN
MAX
MOTOR 1
GND
OFF
LIMITS
LIMIT 2
LIMIT 1
MOTOR 2
GND
LIMITS
LIMIT 2
ON/OFF
BATTERY
JOG
GATE OPEN
COM
GATE CLOSED
GND
OPEN
CLOSE
NO
CLOSE
MAG
LOCK
COM
Jog Switch
NC
PULL
MAGLOCK
OPEN
DELAY
OPEN ONLY NC
PHOTO CLS NC
OFF
2.5 sec
OPEN / CLS NC
(Optional)
1.5 sec
12VDC OUT
GND
OPEN ONLY 10K
UL
ENTRAP
CLS ONLY 10K
MOTOR 2
OPEN / CLS 10K
12VDC OUT
GND
17"
432 mm
Solar
BATTERY
LIGHT
24V
-
+
-
+
-
Regulator
24V
10 Amp
5.75"
(146 mm)
Class of operation.....UL 325 Class I, II, III, IV
Type of gate.....Vehicular swing gate only
Input AC power/amps.....
Switchable: 115VAC / 6 amp, 1 phase
RESET ALARM
230VAC / 2 amp, 1 phase
Power output.....24 VDC
JOG GATE
OPEN / CLOSE
Operating temperature.....-4°F to 158°F (-20°C to 70°C)
Cycles per hour AC input power.....Continuous
Battery back-up cycles.....
(7 Amp/Hr batteries fully charged).....Approx 500 cycles
Entrapment protection.....
- UL 325 Type A Inherent (ERD sensor)
- Inputs for NORMALLY CLOSED (N.C.) or 10K Type
UL 325 Type B1 (photo cell) and Type B2 (sensing edge)
MONITORED when used.
5.75"
(146 mm)
Class of operation.....UL 325 Class I, II, III, IV
Type of gate.....Vehicular swing gate only
Solar power.....
24V Solar Panel
Output: 36V (max) - Open Circuit
RESET ALARM
Power output.....24 VDC
Operating temperature.....-4°F to 158°F (-20°C to 70°C)
JOG GATE
OPEN / CLOSE
Cycles per hour.....Approx. 60
Entrapment protection.....
- UL 325 Type A Inherent (ERD sensor)
- Inputs for NORMALLY CLOSED (N.C.) or 10K Type
UL 325 Type B1 (photo cell) and Type B2 (sensing edge)
MONITORED when used.
OR
MAX Arm/Ultra Arm V1
Need help?
Do you have a question about the MAX ARM and is the answer not in the manual?