Apnea Time - Dräger Infinity Vista Instructions For Use Manual

Table of Contents

Advertisement

Apnea Time

The monitor detects apnea in all monitoring modes provided an apnea time is selected
in the menu. Apnea times are:
z
10 to 30 seconds, in increments of 5.
Upon detection of an apnea event and after the selected apnea time has elapsed, the
monitor triggers a serious alarm.
NOTE:
z
Regardless of the apnea time setting, the monitor continues to alarm for
respiration rate, artifact, and lead-off conditions if the respiration alarm is On.
z
The detection of central apnea is accomplished through impedance
plethysmography.
STEPS: Selecting the Apnea Time