2-6.

System Setup Examples

Chapter 2 A Total System
24
BVP-E10 Series Product Information Manual
2-6-1
Connection Example Using CCU-
550D/ 550DP
Figure 2-6-1-1: Video-signal connections with CCU-550D/ 550DP
Triax cable
CCU-500D/500DP
To an AC power source
Notes
• The maximum power output from the CAMERA
connector of the CCU-550D/ 550DP is 110 watts
(including a maximum cable loss of 10 watts). Do not
connect any equipment, which consumes more than
110 watts of power.
• The BVF-7700/7700P Color Viewfinder cannot be
used because of the power output rating mentioned
above.
• When the BKP-5974 DC Power Unit is connected to
the CCU- 550A/ 550AP, the CA-905K/F large-lens
adaptor cannot be used.
Notes on connections
Triax cable
The triax cable should never be connected to or
disconnected from the CCU-550D/ 550DP when the
power is turned on. Always turn the unit off first.
Video camera
Some switches or controls on the video camera may
not work when the camera is connected to the CCU-
550D/550DP.
CA-570/570P
BVP-E10/E10P/E 10WS/E 10WSP
When a large lens is used
BVF-77/77CE
CA-570/570P
BVP-E10/E10P/E10WS/
E10WSP
BKP-9057
CA-905K/F