Instrument's own
Noise Figure
Frequency
Noise Figure
10 MHz to
< 4.8 dB + (0.00124 * freq in MHz)
3.0 GHz
> 3.0 GHz to
< 12.0 dB
13.2 GHz
>13.2 GHz to
< 16.0 dB
26.5 GHz
Figure 3-1
1. Characteristic values are met or improved on by 90% of instruments with 90% confidence.
1
Characteristic
Noise Figure at 23°C ± 3°C (10 MHz to 3.0 GHz)
Chapter 3
Technical Specifications
Noise Figure and Gain
Noise Figure over a limited
temperature range of 23
< 4.4 dB + (0.00117 * freq in MHz)
< 10.5 dB
< 12.5 dB
o
o
C ± 3
C
93