VAT 653 Series Installation, Operating, & Maintenance Instructions page 9

Pendulum control & isolation valve with devicenet® interface
Table of Contents

Advertisement

Series 65
Position resolution / position control capability
Closing time throttling only (full stroke)
Opening time throttling only (full stroke)
Closing time throttling & isolation (full stroke)
Opening time throttling & isolation (full stroke)
4)
Refer to chapter «Schematics» for details.
5)
PFO = Power Failure Option. Refer to chapter «Behavior in case of power failure» for details.
982156EB
DESCRIPTION OF PRODUCT
DN 100
4"
(65340 - ....)
0.7 s typ.
0.4 s typ.
0.7 s typ.
0.4 s typ.
3 s typ.
4 s typ.
Edition 2019-06-05
DN 160
DN 200
6"
8"
(65344 - ....)
(65346 - ....)
58000 steps
(full stroke)
0.8 s typ.
0.9 s typ.
0.5 s typ.
0.45 s typ.
0.8 s typ.
0.9 s typ.
0.5 s typ.
0.45 s typ.
3 s typ.
3 s typ.
4 s typ.
4 s typ.
DN 250
10"
(65348 - ....)
0.9 s typ.
0.5 s typ.
0.9 s typ.
0.5 s typ.
3 s typ.
4 s typ.
9/110

Advertisement

Table of Contents
loading

This manual is also suitable for:

653 gq series653 aq series653 hq series653 cq series

Table of Contents