Series 65
4.3.3.3
Digital inputs
Pin
13
12
14
4.3.3.4
Digital output
Pin
6
5
7
982156EB
Function
Description
This function will close the valve.
•
The input has priority over the remote interface
•
The input can be inverted
INTERLOCK
•
CLOSE
The input can be switched off
•
The function can be set to function INTERLOCK OPEN
•
INTERLOCK CLOSE has priority over INTERLOCK OPEN
This function will open the valve.
•
The input has priority over the remote interface
•
The input can be inverted
INTERLOCK
•
OPEN
The input can be switched off
•
The function can be set to function INTERLOCK CLOSE
•
INTERLOCK CLOSE has priority over INTERLOCK OPEN
Common for all digital inputs
INPUT
COMMON
See also «»
Function
Signal
type
Digital
VALVE
output
CLOSED
Digital
VALVE
output
OPENED
OUTPUT
Digital
COMMON
common
Edition 2019-06-05
INSTALLATION
Description
This function will indicate that the valve is closed.
•
The output can be inverted
•
The output can be switched off
•
The function can be set to function OPENED or HOLD
This function will indicate that the valve is open.
•
The output can be inverted
•
The output can be switched off
•
The function can be set to function CLOSED or HOLD
Common for all digital output. Connect + or – terminal of source with
common
35/110