Series 65
Command
SENSOR 1 READING
SENSOR 2 READING
SENSOR 1 OFFSET
SENSOR 2 OFFSET
982156EB
INSTALLATION
Service Code
Class ID
Get
14
100
Nominal range is 0 ... 10'000 but it may be scaled.
Refer also to command GAIN and picture on the following page for details.
Get
14
100
Nominal range is 0 ... 10'000 but it may be scaled.
Refer also to command GAIN and picture on the following page for details.
Get
14
100
This command returns the offset voltage adjusted by ZERO.
Value range is -1400 ... +1400 (-1.40V ... +1.40V).
Get
14
100
This command returns the offset voltage adjusted by ZERO
Value range is -1400 ... +1400 (-1.40V ... +1.40V).
Edition 2019-06-05
Instance ID
Attribute ID
Description
1
108
1
109
1
110
1
111
Service
Service
data length
data field
(number of bytes)
2 integer
4 float
2 integer
4 float
2 integer
4 float
2 integer
4 float
75/110