Code
Description
u
v w
Motion controller: Target position can't be
1 5
reached
Motion controller: Position minimal
1 6
conductance cannot be reached
Motion controller: Position to push back the
1 7
Differential Plate cannot be reached
Motion controller: Minimal isolation position
1 8
cannot be reached
2 0 Break slippery detected
SFV: Motion controller failure in master-slave
3 0
communication
4 0 Compressed air error
4 2 Power supply, low voltage detected
SFV: Position deviation axis1 to axis2 at
9 6
homing procedure
SFV: Position deviation axis1 to axis2 at
9 7
operating
9 8 Position error during closing procedure
9 9 Position error at operating
Valve configuration error, not possible to
2 0 0
operate the valve with these configuration
7 0 1 Wrong ident code axis 1
7 0 2 Wrong ident code axis 2
7 0 3 Wrong ident code axis 2 AND axis 1
7 0 4 Wrong ident code axis 3
7 0 5 Wrong ident code axis 3 AND axis 1
7 0 6 Wrong ident code axis 3 AND axis 2
Wrong ident code axis 3 AND axis 2 AND axis
7 0 7
1
7 7 7 Do not operating mode active
1) Mechanical movement problem:
•
Check for differential pressure
•
Remove foreign object in movement area
•
Eliminate tight movement
•
Repair mechanical failure
If you need any further information, please contact one of our service centers. You will find the
addresses on our website: www.vatvalve.com.
84/110
TROUBLE SHOOTING
Solution
• 1)
• Current settings
• 1)
• Check Plate and Seal ring
• Check Parameter "Isolation Position Enter [r]"
• 1)
• Check Different Plate
• Check Parameter "Differential Plate Push Back
Position [r]"
• 1)
• Check Plate and Seal ring
• Check Parameter "Isolation Position [r]"
Replace actuator
Contact vat support
Check compressed air
Check if power supply is ok and is able to deliver needed
power
• O-Ring sticking
• 1)
1)
1)
1)
Contact VAT support
Check wiring
Edition 2019-06-05
Series 65