VAT 653 Series Installation, Operating, & Maintenance Instructions page 8

Pendulum control & isolation valve with devicenet® interface
Table of Contents

Advertisement

Sensor input
Signal input voltage
ADC resolution
Sampling time
Digital inputs (power connector)
Digital outputs (power connector)
4)
Digital inputs
4)
Digital outputs
Input voltage
Input current
4)
Analog outputs
5)
PFO
battery pack
[653 . . - . . C . - . . . . / 653 . . - . . H . - . . . . ]
Compressed air supply
Ambient temperature
Pressure control accuracy
8/110
DESCRIPTION OF PRODUCT
Control and actuating unit (continuation)
-10 ... +10 V / Ri = 100 kΩ
0.1 mV
2 ms
interlock open
input 1
(adjustable with CPA)
input 2
interlock close
(adjustable with CPA)
voltage control
12 ... 24V / 4 ... 8 mA
contact control
24V / 8 mA
valve closed
output 1
(adjustable with CPA)
output 2
valve opened
(adjustable with CPA)
load
max. 70 V / 0.1 A
voltage control
5 ... 24V / 2 ... 10 mA
contact control
3.3V / 2 mA
max. 70 V
max. 0.1 A
0-10 VDC / 1 mA max.
charging time
2 minutes max.
durability
up to 10 years @ 25°C ambient;
refer to «Durability of power fail battery» for details
4 - 7 bar / 55 - 100 psi (above ATM)
0 °C to +50 °C max. (<35 °C recommended)
5 mV or 0.1% of setpoint, whichever is greater
Edition 2019-06-05
connector: SENSOR
connector: POWER
connector: POWER
connector: POWER
connector: POWER
connector: INTERFACE
connector: INTERFACE
connector: INTERFACE
Series 65
982156EB