Amount of charge replaced in the backup battery during the charge
"
portion of the condition cycle (10 second increments). As the battery
ages, this value decreases and allows the system to keep track of low
backup battery conditions that may result from aborted backup bat-
tery condition cycles. Not valid for main battery packs.
Status of charge engine. The condition charge cycle begins with the
"
high charge and ends with topoff charge or any of the following low
charge statuses displayed:
TO DEBOUNCE
"
TOPOFF
"
LO DEBOUNCE
"
LO CHARGE
"
HI DEBOUNCE
"
HIGH CHARGE
"
DISCHARGE
"
INIT CHARGE
"
???
"
Information Logging
An optional command line parameter can be specified to indicate the name
of a file that battery conditioning data may be written to. The following
information is written to the file as the condition cycle progresses:
Voltage of battery being conditioned.
"
System temperature.
"
Condition Cycle Status.
"
Any error encountered during conditioning cycle.
"
6200 and 6210 Hand-Held Computers Troubleshooting Guide 2-7
SECTION 2
Charge input removed during topoff
charge cycle. If reapplied within 10
seconds, topoff resumes.
Battery charge topped off.
Charge input removed during low
charge cycle. If reapplied within 10
seconds, low charge resumes.
Battery is trickle-charged.
Charge input removed during high
charge cycle. If reapplied within 10
seconds, high charge resumes.
Battery charged at high rate.
Battery discharged.
Battery charge cycle initialized.
Battery charge cycle status unknown.
Battery Tips
"