Table B-2. Error Messages and Causes
Error Messages and Causes
Code
Message
-101
Invalid character
- 102
Syntax error
- 103
Invalid separator
- 104
Data type error
- 108
Parameter not allowed
- 109
Missing parameter
- 113
Undefined header
- 123
Numeric overflow
- 128
Numeric data not allowed
- 131
Invalid suffix
- 138
Suffix not allowed
- 141
Invalid character data
- 178
Expression data not allowed
- 211
Trigger ignored
- 222
Data out of range
- 224
Illegal parameter value
- 240
Hardware error
- 310
System error
- 350
Too many errors
- 410
Query interrupted
- 420
Query unterminated
- 430
Query deadlocked
1500
External trigger source
already allocated
2002
Invalid logical address
2003
Invalid word address
2005
No card at logical address
2101
Failed Device
2102
Unable to combine device
2103
Config warning, Device
driver not found
2105
Config error 5, A24 memory
overflow
2108
Config error 8, Inaccessible
A24 memory
Cause
Unrecognized character in specified parameter.
Command is missing a space or comma between
parameters
Command parameter is separated by some
character other than a comma.
The wrong data type (i.e. number, character,
string expression) was used when specifying a
parameter.
Parameter specified in a command which does
not require one.
No parameter specified in the command in
which a parameter is required.
Command header was incorrectly specified.
A parameter specifies a value greater than the
command allows.
A number was specified for a parameter when a
letter is required.
Parameter suffix incorrectly specified
(e.g. .5SECOND rather than .5S or .5SEC).
Parameter suffix is specified when one is not
allowed.
The discrete parameter specified is not allowed
(e.g. TRIG:SOUR INT - INT is not a choice.)
A parameter other than the channel list is
enclosed in parentheses.
Trigger occurred while the Pacer is in the idle
state, or a trigger occurred from a source other
than the specified source.
The parameter value specified is too large or too
small.
The numeric value specified is not allowed.
Hardware error detected during power-on cycle.
Return multimeter to Agilent for repair.
If caused by *DMC, then macro memory is full.
The error queue is full as more than 30 errors
have occured.
Data is not read from the output buffer before
another command is executed.
Command which generates data not able to
finish executing due to a multimeter
configuration erorr.
Command execution cannot continue since the
mainframe's command input, and data output
buffers are full. Clearing the instrument restores
control.
"Event In" signal already allocated to another
instrument such as a Switchbox.
A value less than 0 or greater than 255 was
specified for logical address.
An odd address was specified for a 16 bit read or
write. Always use even addresses for 16 bit
(word) accesses.
A non-existent logical address was specified with
the VXI:READ? or VXI:WRITE command.
VXI device failed its self test.
Device type can not be combined into an
instrument such as a scanning voltmeter or a
switchbox.
ID of device does not match list of drivers
available. Warning only.
More A24 memory installed in the mainframe
than can be configured into the available A24
memory space.
A24 memory device overlaps memory space
reserved by the mainframe's operating system.
Error Messages B-3