:COMMunicate
:SERial[n] [:RECeive]
:SBITs?
Example
:COMMunicate
:SERial[n] :TRANsmit
:AUTO
Parameters
Comments
Example
:COMMunicate
:SERial[n] :TRANsmit
:AUTO?
Comments
Example
SYSTem :COMMunicate :SERial[n] [:RECeive] :SBITs?
SYSTem:COMMunicate:SERial[n][:RECeive]:SBITs? [MIN | MAX] returns:
The current stop bit setting if no parameter is sent.
The maximum allowable setting if MAX is sent.
The minimum allowable setting if MIN is sent.
Querying the current stop bit configuration.
SYST:COMM:SER0:SBITs?
enter statement
SYSTem:COMMunicate:SERial[n]:TRANsmit:AUTO < auto_cntrl> when
ON, sets the transmit pacing mode to be the same as that set for receive pacing.
When OFF, the transmit pacing mode may be set independently of the receive
pacing mode.
Parameter
Parameter
Name
Type
auto_cntrl
boolean
For an Agilent E1324A, AUTO is always ON. Trying to set OFF or 0 will
generate an error.
DIAG:BOOT:COLD will set
Related Commands: SYST:COMM:SER[n]:REC:PACE:PROT,
SYST:COMM:SER[n]:TRAN:PACE:PROT
*RST Condition:
Link transmit pacing with receive pacing
SYST:COMM:SER0:TRAN:AUTO ON
SYSTem:COMMunicate:SERial[n]:TRANsmit:AUTO? returns the current
state of receive to transmit pacing linkage.
For an Agilent E1324A, AUTO is always ON. In this case
always return a 1.
Is AUTO ON or OFF?
SYST:COMM:SER0:TRAN:AUTO?
enter statement
:REC is implied
statement enters 1 or 2
Range of
Values
0| 1| OFF| ON
AUTO to ON.
TRAN:AUTO ON
statement enters the number 1