Condition
Ventilated
There must be at least 4 in. (10 cm) of clearance on
the top and bottom ends (A) of the XPLORE
Charger for air flow and at least 6 in. (15 cm) of
clearance on either side (B). Ventilation openings
on the charger must not be obstructed. If the
charger is mounted in a tight fitting compartment,
the compartment must be ventilated with cut-outs to
prevent the charger from overheating.
B
975-1038-01-01
Requirement
A
B
A
NOTES:
When planning to install the XPLORE Charger, be sure that you
consider the location and orientation carefully. The XPLORE
Charger has an IP rating of IP32 (vertical only as shown in Figure
5 ). This rating means that it meets standards to prevent dripping
water from entering the enclosure and causing shock hazard and
damage to equipment.
The other possible mounting orientations will not prevent the entry
of dripping water and therefore, not suitable for moist
environments without the installation of additional drip protection.
They are only acceptable for use in locations that are always dry.
The environment, therefore, will determine the mounting
orientations that are suitable for each installation. Is the
installation environment one that will always be dry or will
moisture or condensation sometimes enter the area?
ELECTRICAL SHOCK HAZARD
In moist environments, there is a likelihood that condensation will
be present and may drip on to the charger. Use the appropriate
mounting orientations as shown in Figure 5 .
Failure to follow these instructions will result in death or serious
injury.
Preparing For Installation
DANGER
15