Wiring Requirements

ELECTRICAL SHOCK AND FIRE HAZARD
Do not operate the battery charger with damaged or substandard
wiring. Make sure that all wiring is in good condition and is not
undersized. See notes below.
Failure to follow these instructions will result in death or serious
injury.
NOTES:
Wiring and fuse sizes are governed by electrical codes and
standards. Different requirements apply in different countries and to
different types of installations, for example, vessel, truck, home or
RV. It is the responsibility of the installer to ensure that each
installation complies with all applicable codes and standards.
Ensure that wires and fuses or breaker disconnects are correctly
sized. Maximum continuous DC current available from the charger
may be an additional 6–10% above the nominal current rating of
the charger.
975-1038-01-01
DANGER
DC (Battery) Wiring
The following tables show some typical wire sizes for various
cable length runs, based on 3% voltage drop on DC cables, 167 °F
(75 °C) rated wire with wiring being inside the engine compartment
– assumed ambient of 122 °F (50 °C).
Table 1 Battery Cable Examples
Wire Length
Wire Size
(AWG and
(max length one way)
mm
feet
meters
120ADC
5 ft
1.5 m
(21.2 mm
7.5 ft
2.25 m
(26.7 mm
10 ft
3.05 m
NOTE: Extending the DC cable length beyond 7.5 feet (2.25 m)
will affect charging effectiveness as a result of a voltage drop.
Preparing For Installation
Wire Size
(AWG and
2
2
)
mm
)
40ADC
No. 4
n/a
2
)
No. 3
n/a
2
)
n/a
No. 6
2
(13.3 mm
)
17