Adjusting the footplate angle (not illustrated)
1) Loosen and remove the Allen head screws/counter nuts at the top end of the footrest receiver below the seat
bottom.
2) Hold the footplate at the desired angle.
3) Tighten the Allen head screws/counter nuts.

6.8 Adjusting the stand-up function

INFORMATION
► Due to the complexity of the stand-up function, programming changes or mechanical changes to limit
switches and actuators may only be made by qualified personnel with special training.
► Further information is available in the training documents or service manual.
8
C1000 SF
Moving the foot support
1) Loosen and remove the mounting screws on both
sides of the foot support (see fig. 7, item 1).
2) Adjust the height of the foot support to the lower leg
length of the user (3 levels are possible).
3) Insert the mounting screws in the new position and
tighten them.
Moving the actuator
1) INFORMATION: If the distance from the foot
support to the floor becomes too small due to
the adjustment described below, the installed
limit switch (see fig. 7, item 2) stops the stand­
ing function before the desired standing angle
is reached. Extensive mechanical conversion of
the seat is required in order to reach the
desired standing angle again. Note that this
type of adjustment may therefore only be made
by trained, authorised, qualified personnel.
2) Loosen and remove the 2 Allen head screws hold­
ing the actuator (see fig. 7, item 3).
3) Adjust the height of the foot support to the lower leg
length of the user (4 levels are possible).
4) Insert and tighten the Allen head screws at the new
position.
Adjusting the angle of the stand-up function
This stand-up function setting may also be changed by
qualified personnel without specialised training.
The possible angle of the stand-up function can be lim­
ited by adjusting the position of the top limit switch for
the standing actuator.
1) Move the seat into the standing position until the
corresponding screw is freely accessible.
2) Loosen the Allen head screw on the actuator (see
fig. 8, item 1).
3) Slide the ring on the scale up to increase the stand­
ing angle or down to decrease the angle.
4) Retighten the Allen head screw using only minimal
torque.
INFORMATION: The line spacing on the scale is
10 mm. Move the ring by 5 mm at a time and
test the effect. Gradually approach the desired
position.