Transitioning From Grid Mode To Battery Mode; Transitioning From Battery Mode To Grid Mode; Operating Limits - Xantrex Freedom XC 1000 Owner's Manual

Table of Contents

Advertisement

Transitioning from Grid Mode to
Battery Mode
When the unit is operating in grid mode and shore power is lost,
the Freedom XC has less than 20 milliseconds (default) to switch
to operating in battery mode (if the Power button is pressed in the
On position) and starts drawing power from the battery.
The operating mode indicator will change to Battery Mode and the
green Status LED for Battery Mode will light up.
However, if the Power button is in Standby, this transition does
not happen and the display panel turns off.
Transitioning from Battery Mode to
Grid Mode
When the unit is operating in Battery Mode and shore power
becomes available, the Freedom XC begins a 20-second
countdown to verify the stability of the shore power. If shore
power remains stable for a 20-second countdown, at the end of
the countdown, the Freedom XC will switch to shore power mode
within 20 milliseconds and start drawing power from the AC
source.
The operating mode indicator will change to grid mode and the
green Status LED for grid mode will light up.
975-0784-01-01

Operating Limits

These are the operating limits of the Freedom XC:
Power Output
n
Input Voltage
n
Overload Conditions
n
High Surge Loads
n
Over-temperature Conditions
n
Operating Limits
65