Flooring And Hearth Material Selection - Rinnai SS850 Installation Manual

Hide thumbs Also See for SS850:
Table of Contents

Advertisement

GENERAL INSTALLATION INFORMATION

FLOORING AND HEARTH MATERIAL SELECTION

The temperature in front of the fire (200-350 mm x 400 mm wide) can reach up to 40 °C above ambient, therefore
material selection is important. Some guidelines are detailed below. For example, vinyl planks are often only rated
for ambient temperatures. Consequently, the heater would not be suitable for installation directly on that flooring
type.
A
C
D
E
Dim.
Description
Overhang
A
Clearance above
B
Side overhang
C
D
Side clearance
In front
E
F
Clearance to floor
Hearth depth
G
Directly on floor
H
Flue clearance
I
The shaded cells above denote measurements A, B, C, and D. These figures are dependent on each other and the type
of installation. These dimensions may be refined with some specific calculations. These calculations are based on figures
obtained during in-house temperature testing. For more information refer to the next page.
Even if a material is rated above 60 °C it may still be subject to deterioration when exposed to heat cycles. Always
refer to the materials supplier for suitability. The temperatures given assume the heater is operating in a room
temperature of 25 °C or less. Operation in higher ambient temperatures may result in higher surface temperatures.
RINNAI DOES NOT TAKE ANY RESPONSIBILITY FOR ANY DAMAGE OCCURRING
TO ANY ITEMS INSTALLED IN THE VICINITY OF THE HEATER.
WARNING
Rinnai
I
B
F
F
Non-combustible
hearth
Non-combustible materials or
materials rated to 60 °C or higher
above ambient
No restriction as long as materials
within 400 mm to the side (D) are of
the same rating
50 mm min.
No restrictions
50 mm min.
No restrictions
No restrictions
No restrictions
No restrictions
25 mm min.
50 mm (min)
G
Materials rated to a
maximum of 50 °C
above ambient
Not suitable if B is under 250 mm
No restrictions if B is greater than 1000 mm
If B is 300-1000, refer page 9
100 mm min.
No restrictions if D is greater than 400 mm
50 mm min.
150 mm max.
150 mm min.
400 mm min. of non-
combustible material
Not suitable for heat sensitive materials
50 mm min.
8
A
B
Side view
H
Unrated materials,
anything up to 20 °C
above ambient
200 mm min
100 mm min.
100 mm max.
240 mm min.
450 mm min. of non-
combustible material
SS850 Freestanding IM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss850fcanSs850fcal

Table of Contents