Mounting The Inverter; Figure 2-2, Approved Mounting Positions - Magnum Energy MagnaSine Hybrid Mobile Series Owner's Manual

Pure sine wave inverter / charger
Table of Contents

Advertisement

Installation
2.2

Mounting the Inverter

The inverter base can reach a temperature up to 90°C (194°F) and should be mounted on a
noncombustible surface*. This surface and the mounting hardware must also be capable of
supporting at least twice the weight of the inverter. To meet regulatory requirements, the MSH-M
Series must be mounted in one of the following positions (as shown in Figure 2-2):
above or under a horizontal surface (shelf or table),
on a vertical surface (wall) with the DC terminals to the right,
on a vertical surface (wall) with the DC terminals toward the bottom, the MP-HOOD (inverter
hood) installed on the top, and either the ME-CB or MPX-CB conduit box installed on the
inverter's bottom.
Info: The ME-CB or MPX-CB conduit box prevents material from falling out the bottom in
the event of an internal fi re, and also allow suffi cient ventilation to prevent the inverter
from overheating under normal operating conditions. The MP-HOOD helps prevent items
from falling inside—causing damage to the inverter.
Info: Magnum provides backplates for mounting the inverter. These backplates also allow
you to mount the MPX-CB conduit box (PN: BP-S single plate or BP-D, dual plate).
After determining the mounting position, refer to the physical dimensions as shown in Figure
2-3, or use the base of the inverter as a template to mark your mounting screw locations. After
marking the mounting screw locations, mount the unit with appropriate mounting hardware.
* Noncombustible surface – A surface made of material that will not ignite, burn, support combustion, or
release fl ammable vapors when subjected to fi re or heat as per the ASTM E136 standard. For the most part,
these are surfaces that are largely comprised of inorganic materials such as stone, steel, iron, brick, tile,
concrete, slate, and glass. Avoid common building materials such as gypsum board as well as any paint,
wall coverings, or wood.
30
S
HELF OR
M
OUNTED
(
RIGHT SIDE UP
W
ALL
(DC
TERMINALS TO THE RIGHT
Page 9
T
ABLE
)
M
OUNTED
)

Figure 2-2, Approved Mounting Positions

S
T
M
HELF OR
ABLE
OUNTED
(
)
UP SIDE DOWN
© 2013 Magnum Energy, Inc.
W
M
ALL
OUNTED
(DC
TERMINALS
*)
FACING DOWN
*W
HEN THE INVERTER IS
,
MOUNTED IN THIS POSITION
MP-HOOD (
THE
INVERTER
)
HOOD ON TOP
AND EITHER
ME-CB
MPX-CB
THE
OR
(
)
CONDUIT BOX ON BOTTOM
.
MUST BE USED

Advertisement