3.0 Operation; Inverter Mode; Figure 3-1, Power Flow - Inverter Mode - Magnum Energy MagnaSine Hybrid Mobile Series Owner's Manual

Pure sine wave inverter / charger
Table of Contents

Advertisement

Operation

3.0 Operation

The MSH-M Series inverter has two normal operating routines: Inverter mode, which powers
your loads using the batteries, and Standby mode, which transfers the incoming AC current
(i.e., shorepower power or a generator) to power your loads and to recharge the batteries. This
inverter also includes an extensive protection circuitry to shut down the inverter under certain
fault conditions.
3.1

Inverter Mode

When the MSH-M Series is fi rst powered up, it defaults to the OFF mode.
power switch
(Item 1, Figure 1-1)
pressing this switch alternately turns the inverter OFF and ON.
Inverter OFF –
When the inverter is OFF,
loads, and
the status
generator) is connected and qualifi ed on the inverter's AC input, this AC input power will pass
through the inverter to power the AC loads. However, if this AC power is lost, the AC loads will no
longer be powered because the inverter is OFF.
When the inverter is turned ON, it operates either by "searching" or "inverting", depending on the
connected AC loads.
Searching – When the inverter is fi rst turned ON, the automatic Search feature is enabled. This
feature is provided to conserve battery power when AC power is not required. In this mode, the
inverter pulses the AC output looking for an AC load (i.e., electrical appliance). Whenever an AC load
(greater than 5 watts) is turned on, the inverter recognizes the need for power and automatically
starts inverting. When there is no load (or less than 5 watts) detected, the inverter automatically
goes back into Search mode to minimize energy consumption from the battery bank. When the
inverter is searching, the inverter's green LED fl ashes (fast).
Info: The factory default value for the Search feature is 5 watts. It can be turned off or
adjusted from 5 to 50 watts using a remote display.
Inverting –
When a load greater than 5 watts is connected to the inverter output, the MSH-M
Series inverts the DC power from the battery and supplies 120 VAC power to your sub-panel. The
inverter's green LED fl ashes once every 2 seconds (medium fl ash) to indicate it is inverting. The
amount of time the inverter can be inverting and
of AC loads that are connected, and the capacity of the battery bank. Refer to Figure 3-1 to see
the fl ow of power from the DC input to the AC output while in Inverter mode.
HOT IN
CB1
(60A)
NEUTRAL IN
AC GROUND
DC
DC NEGATIVE
IN
DC POSITIVE
Page 29
must be lightly pressed to turn the inverter ON. Subsequently
LED will be OFF. If AC power from an external source (shorepower grid or
AC Hot
Transfer Relay
Neutral-Ground
AC
DC
FET Bridge
Figure 3-1, Power Flow – Inverter Mode
no power is used from the batteries to power the AC
providing power is directly related to the amount
Output
Relay
Transfer Relay
Power Transformer
The momentary ON/OFF
HOT OUT
CB2
(60A)
INV
OUT
NEUTRAL OUT
AC
© 2013 Magnum Energy, Inc.