G Sensor
Enable
Alarm Type
Trigger
Linkage
Checkbox – if selected, enables the device to
monitor for G Sensor trigger events. In case of
G Sensor exceeding the threshold values, this
alarm will be triggered.
DEFAULT SETTINGS:
Checkbox – Unselected
▪
Drop list to select the classification level for the
alarm:
Event
▪
Alarm
▪
DEFAULT SETTINGS:
Alarm
▪
Click the (Setup) button under Trigger to
display the Trigger setup screen to setup the G
Sensor threshold values:
X – numeric text field to set the threshold value
for the G forces along the x-axis.
DEFAULT SETTINGS:
2
▪
Y – numeric text field to set the threshold value
for the G forces along the y-axis.
DEFAULT SETTINGS:
2
▪
Z – numeric text field to set the threshold value
for the G forces along the z-axis.
DEFAULT SETTINGS:
2
▪
Debounce time - Multiple alarms of the same
resource active within the debounce time frame
are regarded as one alarm
DEFAULT SETTINGS:
10 seconds
▪
Click the (Setup) button under Linkage to go
to the Linkage setup screen. This sets up the
video display, recording and snapshot options
associated with this alarm.