Y35HD QUICK INSTALL GUIDE
§
Mount the Y35HD in the vehicle's cabin area where there is environmental control (i.e.
heating and/or air-conditioning).
§
Secure the Y35HD to interior surfaces using the Tek Screws provided for mounting.
§
All cables running through holes in sheet metal (ceiling, bulkhead, etc.) must be
protected with grommets.
§
Ensure that the device is mounted where it is not easily accessible by non-authorized
personnel.
§
DO NOT orient the device such that the drive caddy handle faces the floor of the
vehicle.
§
DO NOT disassemble the device. There are no user serviceable parts inside, and
removing the cover of the Y35HD will void the device's warranty.
§
The Y35HD operates between 8V ~ 36V. Please ensure a regulated, consistent power
source is available for the device.
§
The power supply cable connects to the back of the device through a 9-pin power
input-output connector (CAB000360). The power source should be clean and
(preferably) connected directly from the battery or the power bus.
§
The supplied fuses MUST be used; Failure to use the provided fuses will void the
device's warranty.
§
The 3AMP fuse must be installed close to the power source on the Yellow Ignition wire
on CAB000360
§
The 15AMP fuse must be installed as close as possible to the source on the Red (+12V)
wire on CAB000360
§
GPS Connection - The device is equipped with a connection port for an external GPS
antenna. The GPS must be connected in order to embed vehicle location and vehicle
speed information with the video. The GPS antenna should be installed on the exterior
roof of the vehicle with a clear view of the sky
§
ICD Connection – The 10-pin ICD connector (CAB000390 + CAB000391) is used to
connect the ICD to provide a touch-screen interface.
§
Driver Alert Button Connection - The tri-color Driver Alert Button (G4-TCR-DrvAlert) is
connected using the 4-Pin connector (CAB000371) to the RS485 Converter
(CAB000387) to the sensor cable (CAB000376)
§
External Sensor Module Connection - The ESM is connected to the Sensor Cable
(CAB000387) to provide support for an additional 8 sensor inputs (9 – 16), and 2
sensor
Sensor Wire and Color
SENSOR_IN1 (Yellow)
SENSOR_IN2 (Orange)
SENSOR_IN3 (Black)
SENSOR_IN4 (White)
SENSOR_IN5 (Blue)
SENSOR_IN6 (Red)
SENSOR_IN7 (Green)
SENSOR_IN8 (Brown)
Y35HD QUICK INSTALL GUIDE
CAB000376
Sensor
Brake
Warning Lights
Stop Arm
Door
Left Turn
Right Turn
Extra1
Extra2
- Page 1 -
outputs.
OSD Name
BK
WN
SA
DR
LT
RT
EX1
EX2