H.C Duke & Son Electro Freeze COMPACT Series Operator's Manual page 23

Soft serve freezer
Table of Contents

Advertisement

ELECTRO FREEZE Model CS600
8 Assembly -
HANDLE -
DISPENSE
KNOB -
HAND
Figure 8-3
Figure 8-4
14
continued
ROD - PLUNGER
PLUNGER
O-RING - PLUNGER
O-RING - HEAD
DISPENSE - HEAD
PIN - HANDLE
NOZZLE
Assemble the head assembly
Insert-Assy.
Miix Feed
Assemble the mix feed tube
6. Install and lubricate the O-rings (see
O-ring chart) on the dispensing plunger and
insert into the head (figure 8-3).
7. Install and lubricate the 4-inch head
O-ring.
8. Position the handle in the head
assembly and lock in place with the
handle pin.
9. Snap the nozzle on the mix outlet at
the bottom of the head.
Important:
Do not overtighten the hand knobs.
Excessive force will damage the
head. Tighten the hand knobs finger-
tight only.
10. Install the dispensing head onto
the freezer by sliding the head over the
threaded studs and aligning the square end
of the breaker bar with the square in the
dispensing head. Slide the head into the
cylinder and install the hand knobs, being
careful to tighten evenly and finger tight
only.
NOTE: The plunger rod must be in place for
the freezer to operate in the "CLEAN" or
"AUTO" Mode.
11. Install the plunger rod.
12. Install the O-rings on the mix feed
tube and insert as shown in figure 8-4.
13. Lubricate the O-ring on the insert
and install into the mix feed tube. (No
lubrication is required on the mix feed tube
O-rings.)
184596

Advertisement

Table of Contents
loading

This manual is also suitable for:

Electro freeze compact cs600

Table of Contents