H.C Duke & Son Electro Freeze COMPACT Series Operator's Manual page 35

Soft serve freezer
Table of Contents

Advertisement

ELECTRO FREEZE Shake Model CS600
13
Troubleshooting Charts
PROBLEM
Compressor
1.
will not start –
hums
intermittently
2.
(cycling on
overload)
3.
4.
NOTE: Contact your authorized Electro Freeze distributor for
Keep your freezer in excellent condition. Always contact your
Electro Freeze distributor for replacement parts and
maintenance scheduling.
26
PROBABLE CAUSE
Improperly wired.
Low line voltage.
Open start capacitor. (Single phase only)
Defective compressor
instructions prior to warranty compressor replacement.
— continued
REMEDY
1.
Contact your Electro Freeze Distributor
for service.
2.
Ask power company to increase voltage
to not less than 10% below dataplate
rating or have transformer installed. Have
wire checked for inadequate wire size.
3.
Contact your Electro Freeze Distributor
for service.
4.
Contact your Electro Freeze Distributor
for service.
QUALITY PARTS