H.C Duke & Son Electro Freeze COMPACT Series Operator's Manual page 56

Soft serve freezer
Table of Contents

Advertisement

SANITIZING
1.
Wash and sanitize your hands and forearms.
2.
Prepare 2 gallons (7.6 liters) of sanitizing solution in a
container. The sanitizing solution must be mixed according
to manufacturer's instructions to yield 100 PPM (parts per
million) available chlorine solution (i.e., Stera-Sheen or
equivalent).
3.
Place the mix feed tube assembly and mix float in the
bottom of the hopper pan.
4.
Pour sanitizing solution into the hopper and allow cylinder
to fill. Using a clean brush scrub all sides of the mix
hopper, mix level sensor, mix float, the mix feed tube, and
the mix feed port from the hopper to the cylinder.
5.
Install mix float on mix level sensor. Brush the inside of the
hopper cover with sanitizing solution.
6.
When the cylinder has filled with sanitizing solution,
reconnect power, place the selector switch in the "CLEAN"
position and allow the beater to run for 5 minutes. During
this time period, check for leaks around the head, plunger,
and drain tube.
Do not use the "AUTO" position with sanitizer in the cylinder.
The freezer will be damaged.
7.
Place an empty container under the dispensing head.
Place the selector switch "OFF" and drain the solution by
opening the plunger to allow the cylinder and hopper to
empty. Open and close the plunger at least 10 times while
draining to sanitize the port area of the dispense head.
8.
Sanitizer can be used to sanitize product preparation
container.
Tube-Mix Feed
O-Ring
Figure 3
Mix Feed Tube Assembly
Problem? Contact your local authorized distributor or the freezer manufacturer, Electro Freeze Service Department, 2116
Eighth Avenue, East Moline, IL 61244, (309) 755-4553 or FAX (309) 755-9858.
Important:
O-Ring
Insert-Assy. Mix
Feed
PRIMING
Priming the freezer removes all excess air and sanitizer
from the freezing cylinder and sets the proper overrun for
the first cylinder of product.
1.
Wash and sanitize your hands and forearms.
Note: Always have clean, sanitized hands when
handling mix feed assemblies. Handle only the
top 1" (2.5cm) of mix feed.
2.
Place an empty container under the dispense
head. Install the mix feed tube assembly (see
figure 3) in the "closed" position into the mix feed
drain in the hopper (see figure 4). Pour a mini-
mum of 2-1/2 gallons (9.5 liters)of mix into the
hopper. Hold plunger open and remove mix feed
tube and allow mix to push out the sanitizer. When
pure mix flows from the dispense head close the
plunger. Install the mix feed tube into the mix feed
hopper drain in the "open" position as shown in
figure 4 and place the selector switch to the "Auto"
position.
Important:
Failure to completely remove sanitizer or water
from the freezing cylinder before placing in
"AUTO" will damage the freezer.
3.
Install the hopper cover.
4.
During long idle periods, the white insert tube
should be closed — but remember — when
dispensing product, ensure that the mix feed
insert is OPEN at all times. If not open, the flow of
mix will be restricted. If lubricant blocks the inlet
hole in the tube it would also restrict the flow of
mix.
Pin is in line with hole.
Look through top hole
in tube — you should
see clear through.
Figure 4
Mix Feed Tube
Pin is not in line with hole.
Look through top hole in
tube — you should see the
inner white plastic insert
tube blocking the opening.
Part No. HC184591, Rev. 03 8/12