H.C Duke & Son Electro Freeze COMPACT Series Operator's Manual page 33

Soft serve freezer
Table of Contents

Advertisement

Soft Serve Model CS600
13 Troubleshooting Tables
PROBLEM
Dispensed
1.
product too soft.
(Product
2.
temperature
above 19° F
[-7° C])
3.
4.
5.
Freezer runs
1.
continually and
product gets too
2.
cold.
3.
6.
Compressor and
1.
beater motor
operates only
when
dispensing.
Compressor and
1.
beater motor do
not operate
2.
when
dispensing.
3.
184596
PROBABLE CAUSE
Dirty air filter.
Dirty or blocked condenser, restricted
air flow.
Torque control not set firm enough.
Component failure.
Leak in refrigeration system resulting in
little or no refrigeration.
Plunger not fully closed.
Torque control not set properly or
faulty.
Starter or relay control points stuck.
Suction pressure too low.
Cylinder thermostat setting too warm or
thermostat defective.
Plunger switch(es) defective or out of
adjustment.
Time delay defective.
Defective torque control.
- continued
1.
Clean air filter
2.
Unblock condenser or have cleaned by
your Electro Freeze distributor.
3.
Contact your Electro Freeze distributor
for service.
4.
Contact your Electro Freeze distributor
for service.
5.
Contact your Electro Freeze distributor
for service.
1.
Close plunger completely.
2.
Contact your Electro Freeze distributor
for service.
3.
Contact your Electro Freeze distributor
for service.
6.
Contact your Electro Freeze distributor
for service.
1.
Contact your Electro Freeze distributor
for service.
1.
Contact your Electro Freeze distributor
for service.
2.
Contact your Electro Freeze distributor
for service.
3.
Contact your Electro Freeze distributor
for service.
REMEDY