Troubleshooting By Error Code; Error Codes And Descriptions - Daikin VRV S RXQ4/5ARV1 Service Manual

Table of Contents

Advertisement

Troubleshooting by Error Code

5. Troubleshooting by Error Code
5.1

Error Codes and Descriptions

Error code
Indoor Unit
A0
A1
A3
A6
A8
A9
AF
AH
AJ
C1
C4
C5
C6
C9
CE
CJ
190
Operation
lamp
External protection device abnormality
l
Indoor unit PCB abnormality
l
Drain level control system abnormality
l
Indoor fan motor lock, overload
l
Indoor fan motor abnormality
l
Power supply voltage abnormality
l
Electronic expansion valve coil abnormality, dust clogging
k
Humidifier system abnormality
l
Auto grille unit error
l
Defective capacity setting
Transmission abnormality (between indoor unit PCB and fan PCB)
l
Transmission error
Transmission error (between indoor unit PCB and auto grille control PCB)
Indoor heat exchanger liquid pipe thermistor abnormality
l
Indoor heat exchanger gas pipe thermistor abnormality
l
Combination abnormality (between indoor unit PCB and fan PCB)
Capacity setting abnormality
l
Indoor unit PCB abnormality
l
Suction air thermistor abnormality
k
Infrared presence/floor sensor error
k
Remote controller thermistor abnormality
Description
SiAF332111E
k: ON h: OFF l: Blink
Reference
page
197
198
199
201
203
208
211
212
213
214
215
217
218
220
220
221
222
223
220
224
229
Part 6 Service Diagnosis

Advertisement

Table of Contents
loading

Table of Contents