ESIE15-11A
|
Part 2. Troubleshooting

2. Error code based troubleshooting

Error code
Main
Sub
A0
-
A1
-
A3
-
A6
01
10
11
A7
-
A9
01
02
AF
AH
03
04
05
06
07
08
09
AJ
01
02
C1
01
02
Page 18
VRV4 indoor units
Status outdoor
Reset
Thermo off O
Power
off/on
Thermo off O
Power
off/on
Cool thermo off
Auto
recovery
Thermo off
BRC1..
Thermo off
BRC1..
Thermo off
BRC1..
Warning
BRC1..
Off/on
Thermo off O
Power
off/on
Thermo off O
Power
off/on
Thermo off
BRC1..
Warning
BRC1..
Warning
BRC1..
Warning
BRC1..
Warning
BRC1..
Warning
BRC1..
Warning
BRC1..
Warning
BRC1..
Thermo off
Auto
recovery
Thermo off
Power
reset
Thermo off
Auto
recovery
Thermo off
Auto
recovery
2. Error code based troubleshooting
Cause
Solution
Fault board
Check setting 22-1-3: T1-T2 NC.
If correct, indoor board fault.
Fault Eeprom
Replace board.
Float switch open
Check float switch status, drain
during thermo on
pipe no blockage, drain pipe raiser
(cooling)
< 600 mm.
Fan motor locked
Rpm counter no signal from motor
to indoor main board when output.
Fan motor overcurrent
Check motor power circuit.
Replace fan motor / indoor board.
Fan motor locked
Rpm counter no signal at off
condition.
No detection contact
Check swing motor run when
swingmotor
output 230VAC.
Check contact position detection
open & close.
EV motor fault
Check signal board to expansion
detection
valve.
EV body leakage
Check temperature coil sensor at
close EV cooling other indoor
Float switch open
Check for drain water returning
during thermo off
from other indoor, expansion valve
correct closing thermo off.
Communication error
Check wire harness connections.
main PCB / self
cleaning PCB
Dust detection sensor
Check wire harness connections.
error
Dust collection error
Check for clogging by dust
between brush-arm and dust
collector box.
Air filter rotation error
Check rotation mechanism air
filter.
Damper rotation error
Check rotation mechanism
damper.
Filter cleaning time
Filter auto cleaning program could
error
not be performed 24 hr operation.
Auto self cleaning
Check field settings to enable auto
disabled
filter cleaning.
Capacity adaptor
Add corresponding capacity
missing
adaptor onto spare part PCB
Incorrect expansion
Use correct expansion valve
valve motor
motor (between gear type and
direct drive).
Communication error
Check for communication between
main PCB / inverter
main PCB and inverter PCB fan
PCB fan motor
motor.
Communication error
Check for communication between
main PCB / auxiliary
main PCB and inverter PCB fan
PCB
motor.